Sample Clock Status Display

The following is the output of a status program written for the Heath GCW-1001 Most Accurate Clock II. The information was taken at 9:50PM EDT (0150Z) on April 22, 1999. The program utilizes information returned by the undocumented "@" command:

           H e a t h   G C W - 1 0 0 1   S t a t u s   S u m m a r y
           =========================================================
0 hours, 0 minutes since last WWV adjustment.  Time now is 09:50:34.4 PM.
Last accumulated error was 0.00ms.  Current timebase divisor is 3C3 (963).
The current UT1 correction is +0.6 seconds.  The clock was set by WWV.

UT1 switch is OFF.   UTC switch is OFF.        DST switch is ON. 
TEST switch is OFF.  MINUTES switch is OFF.    HOURS switch is OFF.
TRIM DN LED is OFF.  HI SPEC LED is ON.        TRIM UP LED is OFF.
CAPTURE LED is ON.   Display mode is 12 hour.  HI SPEC expires in 4 minutes.

 Daylight Savings Time bit #2 is set
 Daylight Savings Time bit #55 is set
 Time zone setting: UTC - 5 hours
 Propagation delay setting: 1500 miles (7.50ms)

10MHz Propagation and Timebase Trimming Summary (10 valid frames this hour):

UTC     00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23
-------------------------------------------------------------------------------
Packets  0  1  0  0 12  0  0  0  0  0  0  0  0  0  0  1  8  0  0  0  0  4  2  0
-------------------------------------------------------------------------------
Trim     3  3  3  3  3  3  3  3  3  3  3  3  3  3  3  3  3  3  3  3  3  3  3  3
Factor   C  C  C  C  C  C  C  C  C  C  C  C  C  C  C  C  C  C  C  C  C  C  C  C
         3  4  4  4  4  4  4  4  4  4  4  4  4  4  4  3  2  2  2  2  2  3  3  3